NL
C4
C3
C2
C1
M
C1
C2
LN
F430/4
F430/2
C1 C2 C3 C4
ART. F430/4
1
1 2 3 4
2 4 53
5
C1 C2
ART. F430/2
1
1 2 3 4
2 43
MY HOME
279
Energy management
SINGLE CIRCULATION
PUMP
C1= fan-coil solenoid valve
C2= minimum ventilation speed
C3= average ventilation speed
C4= maximum ventilation speed
CIRCULATION PUMP
Wiring diagram for connecting
the circulation pumps to the
corresponding actuator.
ZONE 12
A system which can provide both
heating and cooling is controlled by a
single pump.
next >>
HEATING AND COOLING
Wiring diagram for connecting the
fan-coil to the actuator for zone
12 heating/cooling. To control the
fan-coils belonging to all the other
zones replicate the same connection,
correctly configuring the actuator
corresponding to the zone as
indicated in the configuration tables.